Roll-In Blast Chiller / Freezer Rooms

Blast Chillers and Blast Freezers

Where production moves trolley by trolley, blast chilling happens in a room the trolley is wheeled straight into. These rooms process 140 to 200 kg per cycle for large caterers, central kitchens and food production plants.

The family has two models. VBL20 measures 170x126x214 cm and takes one trolley of 20 GN 2/1 trays, chilling 140 kg and freezing 120 kg per cycle. VBL40 measures 170x171x214 cm and takes two trolleys with 40 GN 2/1 trays in total, chilling 200 kg and freezing 180 kg. The cycles are defined as +90 °C to +3 °C in 90 minutes and +90 °C to -18 °C in 270 minutes. Insulation is 120 mm, the body is AISI 304 stainless steel and the refrigerant is R404A. The supply is three-phase: 380–420V at 50Hz or 440–480V at 60Hz.

Choose VBL20 for one trolley per cycle and VBL40 for two. The catalogue specifies a split refrigeration unit, a stainless steel ramp and a programmable HACCP controller; trolleys are not included.

VBL40 170x171x214 304 120 mm R404A 380-420V 3Ph 50Hz / 440-480V 3Ph 60Hz 1 90/3 90/-18 38 2 Trolleys / 40 pcs GN 2/1 2 Araba 40 Ad. GN 2/1 2 Trollies 40 Pcs. GN 2/1 200 180 50
VBI20 170x126x214 304 120 mm R404A 380-420V 3Ph 50Hz / 440-480V 3Ph 60Hz 1 90/3 90/-18 38 1 Trolley / 20 pcs GN 2/1 140 120

Frequently Asked Questions

How is the capacity of a blast chiller room determined?

Selection of a blast chiller / freezer room is based on the number of trolleys and the weight of product to be processed at once. VBL20 takes one trolley (20 GN 2/1 trays) and chills 140 kg or freezes 120 kg per cycle. VBL40 takes two trolleys (40 trays) and chills 200 kg or freezes 180 kg.

How much space does a blast chiller room need?

External dimensions of the blast chiller room models are 170 cm wide, 126 cm deep and 214 cm high for VBL20, and 170x171x214 cm for VBL40. Beyond this footprint, the layout should also allow room in front of the door for manoeuvring the trolley.

Which operations is a blast chiller room suited to?

A blast chiller / freezer room suits large caterers, central kitchens, hotel production kitchens and food production plants that move product on GN 2/1 trolleys and need to chill 140 to 200 kg per cycle. For smaller volumes the reach-in models are sufficient.

What electrical connection does a blast chiller room require?

The blast chiller / freezer room models run on a three-phase supply: 380–420V at 50Hz or 440–480V at 60Hz. The refrigerant is R404A and insulation thickness is 120 mm. The refrigeration unit is a split type; the catalogue states it is calculated for a distance of up to 5 metres from the room.

© 2026 FRENOKS ENDÜSTRİYEL SOĞUTMA SANAYİ VE TİCARET A.Ş. ALL RIGHTS RESERVED.

Cookie Preferences

Frenox uses cookies to give you a better experience. For details, please see our Cookie Policy.